Product Specifications:Temperature measurement range : -10 ºC ~ +50ºC (-14ºF ~ +122 ºF)Temperature measurement accuracy : ±2 ºC (3.6ºF)Temperature resolution : 0. 1 ºC (0.1ºF)Humidity measuring range:

Product Specifications:

Temperature measurement range : -10 ºC ~ +50ºC (-14ºF ~ +122 ºF)

Temperature measurement accuracy : ±2 ºC (3.6ºF)

Temperature resolution : 0. 1 ºC (0.1ºF)

Humidity measuring range: 10%~99% RH

Humidity measuring accuracy: 10% RH

Humidity resolution : 1%


Battery: AAA 1.5V 1PCS

Basic functions:

Temperature / Humidity

ºC / ºF temperature switch display

The maximum / minimum temperature

and humidity memory function

12/24 hour clock

The whole point time keeping function

Daily alarm

Calendar display


Operation manual:

1. Push down battery cover “OPEN” on meter back side, and install battery.


2. Time setting: In the initial state, press [MODE] till there is a Di sound, and the

number of minute start flashing; press [ADJ] to adjust number, press [MODE] to set

minute number; then the number of hour start flashing. Repeat above steps to set

hour number, and enter hour system setting. Press [ADJ] to choose "12/24" hour

system, press [MODE] to set. Then it come to month (M) and day (D) setting, repeat

above steps to set date.


3. Alarm setting: In normal clock mode (the two points between hour and minute

flash), press [MODE] once, switch the display for alarm clock mode (clock and

minutes between two points in not flashing). Press [ADJ] to switch " " (alarm) /

"ALarm" (hourly alarm) function; press [MODE] till there is a Di sound, and the

number of minute start flashing, you can set the alarm time (same steps as time

setting), press [MODE] once to exit alarm time setting. When alarm, meter sounds for

one minute, or press any button to stop alarm; When hourly alarm, meter only sounds

“DiDi”.


4. Press [MEMORY] button to display the MAX/MIN/Current temperature/humidity.


5. Memory clear function: in MAX or MIN state, press [MEMORY] for long time till a


Di sound to clear MAX/MIN data.


Temperature measurement range : -10 ºC ~ +50ºC (-14ºF ~ +122 ºF)

Temperature measurement accuracy : ±2 ºC (3.6ºF)

Temperature resolution : 0. 1 ºC (0.1ºF)

Humidity measuring range: 10%~99% RH

Humidity measuring accuracy: 10% RH

Humidity resolution : 1%


Packing details: Double  blister

Size of mater carton: 38x45x55cm

Packing quantity :100 pcs/ctn

G.W.: 21kgs  N.W.: 18kgs